SYS-301 · SYSTEM
Cabin / hotel automation and room-control system
객실·호텔 자동화·룸제어 시스템
The in-cabin controls for lighting, temperature and do-not-disturb status, networked so the hotel side manages comfort and energy across thousands of rooms.
- Public record ID
- SYS-301
- Functional Category
- CAT-17 · Accommodation, Hotel & Domestic Systems
- Released Component records
- 6
- Evidence state
- Reference taxonomy — not project verified
SYSTEM CONTEXT
- Functional Category
- CAT-17 Accommodation, Hotel & Domestic Systems
- Family reference-profile markers
- ● 1 Standard · ○ 5 Common · △ 1 Variant · 14 unmarked
- Component coverage
- 6 released source-BOM records
- Relationship meaning
- Family markers describe reference applicability. Component links are released source-BOM listings and do not assert complete engineering containment.
FAMILY REFERENCE APPLICABILITY
Family profiles carrying a source marker.
Unmarked Families are not listed; an unmarked cell means “not normally fitted” in the source Family profile, not confirmed absence from a vessel.
Cruise and passenger ships
● StandardView Family profile →ROPAXRo-ro passenger ferries
○ Common / conditionalView Family profile →OFFSHORE SUPPLY / WINDPSV, AHTS, OSV/SOV and CTV
○ Common / conditionalView Family profile →OFFSHORE CONSTRUCTION / SUBSEACable, pipe, diving, subsea construction, WTIV and intervention vessels
○ Common / conditionalView Family profile →OFFSHORE PRODUCTION / PROCESS / STORAGEDrillship, FPSO, FSO, FSU, FLNG and FSRU
○ Common / conditionalView Family profile →RESEARCH / SURVEY / ICE / SPECIALResearch, hydrographic, seismic and icebreaking vessels
△ VariantView Family profile →YACHTLarge yachts and superyachts
○ Common / conditionalView Family profile →RELEASED SOURCE-BOM LISTING
Released Component records.
Coverage is partial and Family-independent: selecting a Family does not alter the Component records linked to this System.
Cabin room-control units
객실 룸제어 유닛The controller in each cabin managing its lighting, temperature and service status.
Reference pattern · Per cabinView Component record →COMP-748 · Instrument / SensorOccupancy and environmental sensors
재실·환경센서Sensors detecting occupancy and conditions, letting empty cabins fall back to energy-saving settings.
Reference pattern · Per cabinView Component record →COMP-749 · ActuatorLighting / HVAC actuators
조명·HVAC 액추에이터The actuators executing the room controller's commands on lights, valves and dampers.
Reference pattern · Per cabinView Component record →COMP-750 · Instrument / SensorDoor and access interfaces
도어·출입 인터페이스The interfaces linking cabin door and key-card status into the hotel system.
Reference pattern · Per cabinView Component record →COMP-751 · Panel / ElectronicsCentral hotel-automation server
중앙 호텔자동화 서버The redundant servers coordinating thousands of cabins as one managed estate.
Reference pattern · Redundant pair typicalView Component record →COMP-752 · Panel / ElectronicsRoom-control network gateways
룸제어 네트워크 게이트웨이The gateways connecting cabin controllers to the central system across the ship's networks.
Design dependent · As requiredView Component record →