SYS-212 · SYSTEM
Cargo pump-room ventilation system
화물펌프실 통풍 시스템
Powerful extraction fans that continuously change the air in the cargo pump room, preventing flammable vapour from accumulating in this enclosed, high-risk space.
- Public record ID
- SYS-212
- Functional Category
- CAT-01 · Cargo Containment & Handling Systems
- Released Component records
- 5
- Evidence state
- Reference taxonomy — not project verified
SYSTEM CONTEXT
- Functional Category
- CAT-01 Cargo Containment & Handling Systems
- Family reference-profile markers
- ● 0 Standard · ○ 2 Common · △ 0 Variant · 19 unmarked
- Component coverage
- 5 released source-BOM records
- Relationship meaning
- Family markers describe reference applicability. Component links are released source-BOM listings and do not assert complete engineering containment.
FAMILY REFERENCE APPLICABILITY
Family profiles carrying a source marker.
Unmarked Families are not listed; an unmarked cell means “not normally fitted” in the source Family profile, not confirmed absence from a vessel.
RELEASED SOURCE-BOM LISTING
Released Component records.
Coverage is partial and Family-independent: selecting a Family does not alter the Component records linked to this System.
Pump-room supply and exhaust fans
펌프-room supply and exhaust 팬The fans that force continuous air changes through the pump room so leaked vapour never accumulates to a dangerous level.
Design dependent · As required / design dependentView Component record →COMP-059 · Piping / FittingVentilation ducts and trunks
환기 덕트·트렁크The duct runs that deliver air to the pump-room bottom and draw it from the levels where heavy vapour collects.
Design dependent · As required / design dependentView Component record →COMP-060 · ValveFire / gas dampers
화재·가스 댐퍼Closable flaps in the pump-room ducts that seal the ventilation path if fire or gas requires the space to be isolated.
Design dependent · As required / design dependentView Component record →COMP-061 · Panel / ElectronicsGas-detection interlocks
가스 검지 인터록The logic tying gas detection to the ventilation — alarms, fan behaviour and entry restrictions follow automatically when gas is sensed.
Design dependent · As required / design dependentView Component record →COMP-062 · Panel / ElectronicsVentilation control panel
Ventilation 제어반The panel showing fan running status and airflow, with the pre-entry ventilation controls.
Design dependent · As required / design dependentView Component record →