SYS-183 · SYSTEM
Fire door control system
방화문 제어
The release system for self-closing fire doors on passenger ships: doors normally held open close automatically or on bridge command, dividing the ship into fire zones.
- Public record ID
- SYS-183
- Functional Category
- CAT-15 · Fire Detection & Fire-Fighting Systems
- Released Component records
- 6
- Evidence state
- Reference taxonomy — not project verified
SYSTEM CONTEXT
- Functional Category
- CAT-15 Fire Detection & Fire-Fighting Systems
- Family reference-profile markers
- ● 3 Standard · ○ 0 Common · △ 0 Variant · 18 unmarked
- Component coverage
- 6 released source-BOM records
- Relationship meaning
- Family markers describe reference applicability. Component links are released source-BOM listings and do not assert complete engineering containment.
FAMILY REFERENCE APPLICABILITY
Family profiles carrying a source marker.
Unmarked Families are not listed; an unmarked cell means “not normally fitted” in the source Family profile, not confirmed absence from a vessel.
RELEASED SOURCE-BOM LISTING
Released Component records.
Coverage is partial and Family-independent: selecting a Family does not alter the Component records linked to this System.
Fire doors
방화문The rated doors dividing the accommodation into fire zones, holding fire back for a specified time.
Design dependent · As requiredView Component record →COMP-685 · ActuatorDoor closers
도어 클로저The closers that shut each door reliably, since a wedged-open fire door is no boundary at all.
Reference pattern · Per doorView Component record →COMP-686 · ElectricalHold-open magnets
홀드오픈 마그넷Magnets holding doors open for daily convenience and releasing them automatically when the fire alarm operates.
Design dependent · As requiredView Component record →COMP-687 · Panel / ElectronicsFire-door release / control panel
방화문 해제·제어반The panel releasing all doors together from the bridge and showing their status.
Reference pattern · 1 or moreView Component record →COMP-688 · Instrument / SensorDoor status switches
문 상태 스위치Switches reporting whether each monitored door is actually closed.
Reference pattern · Per monitored doorView Component record →COMP-689 · Safety deviceLocal release devices
현장 해제장치Local means of releasing doors at the door itself or by zone.
Reference pattern · Per door / zoneView Component record →